    Large Screen Patient Monitoring Devices , Spo2 Patient Care Monitoring System

    Ask Lasest Price
    Brand Name : STATEMED
    Model Number : STT15-MPM44
    Certification : CE
    Price : competitive
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 100 sets per month
    Delivery Time : 10 working days
    • Product Details
    • Company Profile

    Large Screen Patient Monitoring Devices , Spo2 Patient Care Monitoring System

    Doctor Diagnose Portable Multi Parameter Patient Monitor CE Approved

    Battery

    Battery typeLithium battery 11.1V/4.4Ah

    Recharge time
    (90% charge time)

    ≥4 hour
    Use time3hours



    Work Environment

    Environment temperature

    Working 5℃~+40℃
    Transportation and storage -40℃~+55℃

    Relative humidity

    Working ≤85%
    Transportation and storag ≤95%

    Atmospheric pressure

    Working 700hpa~1060hpa
    Transportation and storag 500hpa~1060hpa



    ECG

    LeadStandard Three leadsR,L,F, lead mode :Ⅰ,Ⅱ,Ⅲ
    Standard Five leads

    R,L,F,N,C,
    Lead mode :Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V;

    Sensitivity2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,40mm/mV,erro≤±3%
    Scan speed12.5,25,50mm/s three level,erro ≤±10%
    Adjustable screen aspect ratio0.05~3.2
    Lead off condition detectedU=2V I=0.04uA
    Active noise suppressionIn patients who have not applied current
    Tall T-wave suppression1.4mV
    Inner voice<30μVP-P
    Input impedance≥2.5MΩ
    Input loop current≤0.1μA
    Endure electrode polarizing voltage±300mV
    ECG signal input range±5mV
    Measurement modeDiagnosis mode,monitoring mode,operation mode
    Frequency property

    diagnosis mode 0.05~130HZ
    monitoring mode 0.5~40HZ
    operating 1~20HZ

    CMRR

    Diagnosis mode ≥80dB
    Monitoring mode ≥90dB
    Operating mode ≥100dB

    HR measurement range

    Adult 30~250bpm
    Neonate /pediatrics 30~300bpm

    HR accuracy±2%
    HR sensitivity>200μV
    Heart rate calculationTake 4 to 12 R-wave cycle averaged
    Refresh time heart rate1S
    Heart rate response time

    80-120 BPM:range 4-7s
    Average 4-7s
    80-40 BPM: range 4-7s
    Average 4-7s

    Alarm range0~301bpm,upper and lower limit can be adjusted continuously
    Alarm indicatorAudial and visual alarm
    Heart rate too fast startup time of the alarm

    Range :4-6s
    Average :4-6S

    ProtectionIsolated immunity voltage 4000V,50/60HZImmunity of electronic surgical Anti-defibrillation
    Protection and recovery for defibrillation effectIn the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S.
    Electrode polarization recovery time after the fibrillationIn the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S.
    Surgical interference of electrical recovery timeIn the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S.
    No overshoot pacemaker pulse suppression:
    Extent±2mV~±700mV,Pulse width 0.1ms~2msQRS waveDisplay
    a)Single pacing pulse6060±2bpm
    3030±2bpm
    0--
    b)With normal QRS-T pacing the pacing pulse6060±2bpm
    3030±2bpm
    0--
    c)QRS has an invalid pacing mode pacing pulse. In all cases, overshoot (a0) pacing rate should be less than 5% overshoot and settling time must be less than 5μs. Rise and fall time of the pulse width should be 10% but not more than 100μs, and the pacing pulse starting time should be the starting point in the QRS complex prior to or shorter than 40ms at 40ms.6060±2bpm
    3030±2bpm
    0--
    Beware of the room pacing pulses have the same ventricular pacing pulse amplitude and duration, and ventricular pacing pulses than 150ms to 250ms in advance6060±2bpm
    3030±2bpm
    0--
    Typical minimum input slew rate50V/s RTI























    Quality Large Screen Patient Monitoring Devices , Spo2 Patient Care Monitoring System for sale